<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Semnan University Press</PublisherName>
				<JournalTitle>Journal of Modeling and Simulation in Electrical and Electronics Engineering</JournalTitle>
				<Issn>2821-0786</Issn>
				<Volume>6</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>12</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Low-Power FPGA-Based Quantized Neural Network Accelerator for Real-Time Arrhythmia Detection from Single-Lead ECG</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>1</FirstPage>
			<LastPage>9</LastPage>
			<ELocationID EIdType="pii">10960</ELocationID>
			
<ELocationID EIdType="doi">10.22075/mseee.2026.40918.1267</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Amir Hossein</FirstName>
					<LastName>Rahmani</LastName>
<Affiliation>Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran.</Affiliation>
<Identifier Source="ORCID">0009-0003-3401-2720</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>04</Month>
					<Day>26</Day>
				</PubDate>
			</History>
		    <Abstract>Arrhythmia detection from long-term electrocardiogram (ECG) recordings is essential for early diagnosis of cardiovascular diseases in portable and wearable monitoring systems. This paper presents a low-power hardware accelerator for real-time beat-level arrhythmia classification using an 8-bit quantized 1D convolutional neural network (QNN) implemented on a Xilinx Artix‑7 FPGA. The network is trained and evaluated on the MIT-BIH Arrhythmia Database under an inter-patient scheme and classifies beats into three clinically relevant categories: normal (N), ventricular ectopic (V), and supraventricular ectopic (S). After quantization-aware training, the 8-bit fixed-point model achieves 98.4% overall accuracy, with 99.1% sensitivity and 98.7% positive predictive value (PPV) for N beats, and 96.6% sensitivity with 95.9% PPV for V beats on the held-out test set. The hardware accelerator exploits parallel multiply–accumulate units, on-chip BRAM reuse, and a streaming dataflow to process each 256-sample beat segment in 8.5 µs at 100 MHz, corresponding to a throughput of approximately 118 k beats/s while consuming 0.92 W power. Compared with a 32-bit floating-point implementation on an ARM Cortex-A9 processor, the proposed design provides about 9.3× speedup and 27× lower energy per beat, making it suitable for wearable and home monitoring systems.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">ECG</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Arrhythmia Detection</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Quantized Neural Network</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">FPGA Accelerator</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Low Power Design</Param>
			</Object>
		</ObjectList>