<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Semnan University Press</PublisherName>
				<JournalTitle>Journal of Modeling and Simulation in Electrical and Electronics Engineering</JournalTitle>
				<Issn>2821-0786</Issn>
				<Volume>6</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>12</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Low-Power FPGA-Based Quantized Neural Network Accelerator for Real-Time Arrhythmia Detection from Single-Lead ECG</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>1</FirstPage>
			<LastPage>9</LastPage>
			<ELocationID EIdType="pii">10960</ELocationID>
			
<ELocationID EIdType="doi">10.22075/mseee.2026.40918.1267</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Amir Hossein</FirstName>
					<LastName>Rahmani</LastName>
<Affiliation>Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran.</Affiliation>
<Identifier Source="ORCID">0009-0003-3401-2720</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>04</Month>
					<Day>26</Day>
				</PubDate>
			</History>
		    <Abstract>Arrhythmia detection from long-term electrocardiogram (ECG) recordings is essential for early diagnosis of cardiovascular diseases in portable and wearable monitoring systems. This paper presents a low-power hardware accelerator for real-time beat-level arrhythmia classification using an 8-bit quantized 1D convolutional neural network (QNN) implemented on a Xilinx Artix‑7 FPGA. The network is trained and evaluated on the MIT-BIH Arrhythmia Database under an inter-patient scheme and classifies beats into three clinically relevant categories: normal (N), ventricular ectopic (V), and supraventricular ectopic (S). After quantization-aware training, the 8-bit fixed-point model achieves 98.4% overall accuracy, with 99.1% sensitivity and 98.7% positive predictive value (PPV) for N beats, and 96.6% sensitivity with 95.9% PPV for V beats on the held-out test set. The hardware accelerator exploits parallel multiply–accumulate units, on-chip BRAM reuse, and a streaming dataflow to process each 256-sample beat segment in 8.5 µs at 100 MHz, corresponding to a throughput of approximately 118 k beats/s while consuming 0.92 W power. Compared with a 32-bit floating-point implementation on an ARM Cortex-A9 processor, the proposed design provides about 9.3× speedup and 27× lower energy per beat, making it suitable for wearable and home monitoring systems.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">ECG</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Arrhythmia Detection</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Quantized Neural Network</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">FPGA Accelerator</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Low Power Design</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mseee.semnan.ac.ir/article_10960_018d335e8cc3c437150a76fa6f052a44.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Semnan University Press</PublisherName>
				<JournalTitle>Journal of Modeling and Simulation in Electrical and Electronics Engineering</JournalTitle>
				<Issn>2821-0786</Issn>
				<Volume>6</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>12</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Comparative Thermal Loss Analysis of a Dual Active Bridge Converter With and Without LLL Resonant Tank for EV Charger Applications</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>11</FirstPage>
			<LastPage>19</LastPage>
			<ELocationID EIdType="pii">10945</ELocationID>
			
<ELocationID EIdType="doi">10.22075/mseee.2026.40617.1254</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Amir Hossein H</FirstName>
					<LastName>Najaei</LastName>
<Affiliation>Faculty of Electrical and Computer Engineering, Semnan University, Semnan, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Naser</FirstName>
					<LastName>Eskandarian</LastName>
<Affiliation>Faculty of Electrical and Computer Engineering, Semnan University, Semnan, Iran.</Affiliation>
<Identifier Source="ORCID">0000-0002-6718-5375</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>02</Month>
					<Day>16</Day>
				</PubDate>
			</History>
		    <Abstract>Dual Active Bridge (DAB) DC–DC converters are commonly used in high-power isolated systems, including on-board and off-board electric vehicle chargers, because of their inherent bidirectional power transfer capability and compact design. However, as charging power levels and efficiency targets continue to rise in modern EV infrastructures, the associated increase in semiconductor losses and device temperatures makes thermal performance a critical design concern. Despite the advantages, traditional DAB converters with single-phase shift (SPS) control tend to incur considerable switching losses, especially at high power levels, which can raise semiconductor junction temperatures. In particular, the lack of a detailed, application-oriented comparison between the thermal loss behavior of conventional DAB converters and resonant-assisted variants under realistic EV charging conditions limits designers’ ability to select the most thermally efficient topology. For this reason, the power-loss characteristics and thermal response of a conventional DAB converter, related to its switches, are evaluated and compared with those of an LLL-tank-assisted DAB topology. The two converter topologies are modeled in MATLAB/Simulink and PLECS and tested under identical operating conditions, including power level and control method, so that the results can be directly compared. Semiconductor losses are then estimated by considering both conduction and switching components, with switching energy values taken from the IGBT manufacturer’s datasheet. Junction temperature is then estimated through a steady-state thermal resistance model that relates total power dissipation to ambient conditions. The influence of the LLL resonant tank on converter current profiles and thermal stress is analyzed. Simulation results show that introducing the LLL resonant tank reduces switching and conduction losses, thereby lowering the junction temperature of the power semiconductor devices compared with the conventional DAB converter. This improvement is achieved without altering the original SPS control approach. The outcomes of this work offer valuable guidance for thermally optimized design of high-power isolated DC–DC converters used in electric vehicle charging systems, bridging an important gap between efficiency-oriented analysis and comprehensive thermal loss evaluation for practical EV charger applications. This work presents a systematic comparative thermal loss analysis of a Dual Active Bridge (DAB) converter operating with and without an LLL resonant tank, specifically for high-power EV charger applications. Unlike prior studies that primarily focus on efficiency enhancement or soft-switching performance of resonant-assisted DAB topologies, this study provides a detailed device-level evaluation of thermal and loss distribution under identical operating conditions. The proposed comparison framework quantifies conduction and switching losses and the resulting impact on system-level thermal management requirements. This approach enables a clearer understanding of the trade-offs between conventional DAB and LLL-assisted configurations in terms of efficiency, thermal performance, and practical constraints for EV charger implementation.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Dual Active Bridge Converter</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">LLL Resonant Tank</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Switching Loss Analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermal Modeling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Junction Temperature</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Electric Vehicle Chargers</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mseee.semnan.ac.ir/article_10945_122915b6774a4467be946ddae541af52.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Semnan University Press</PublisherName>
				<JournalTitle>Journal of Modeling and Simulation in Electrical and Electronics Engineering</JournalTitle>
				<Issn>2821-0786</Issn>
				<Volume>6</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>12</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Real-Time Implementation and Simulation of Comparative Fuzzy-PID Controllers for a Fluid Level System</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>21</FirstPage>
			<LastPage>34</LastPage>
			<ELocationID EIdType="pii">10951</ELocationID>
			
<ELocationID EIdType="doi">10.22075/mseee.2026.41616.1284</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Ali</FirstName>
					<LastName>Hosseini Laqa</LastName>
<Affiliation>Department of Electrical and Computer Engineering, Faculty of Electrical Engineering, Isfahan University of Technology, Isfahan, Iran.</Affiliation>
<Identifier Source="ORCID">0009-0003-4318-1534</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>06</Month>
					<Day>14</Day>
				</PubDate>
			</History>
		    <Abstract>This paper develops and compares three control strategies for a water level process: a conventional proportional-integral-derivative (PID) controller, a PID controller embedded in a Smith Predictor structure, and a Fuzzy PID controller. Experiments are carried out on a TE3300 process trainer, where a differential pressure transmitter reports the level, and an electro-pneumatic valve sets the inlet flow. First-order plus time delay (FOPTD) and second-order plus time delay (SOPTD) models are fitted to step-response data recorded on the setup, and the second-order model serves as the common plant against which all three controllers are evaluated. The conventional controller is tuned by the internal model control (IMC) method, and the inner controller of the predictor is independently retuned for the delay-free plant, a step that keeps the comparison focused on control structure rather than on inherited tuning. The Fuzzy PID controller is built on a zero-order Sugeno inference system, and three distinct control surfaces are constructed and tested. All three controllers are subsequently deployed on the physical setup and run in real time through an Open Platform Communications (OPC) interface, which introduces a delay of approximately five seconds between the controller and the plant. The paper reports what this delay compensation is worth in practice and examines how the geometry of the fuzzy control surface balances the error accumulated during a transient against the speed of correction and the resulting valve activity.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Fuzzy PID control</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Smith Predictor</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">System identification</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Control Surface geometry</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Time delay</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Water level system</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mseee.semnan.ac.ir/article_10951_0561bc7ecba98e39ca7994f93311ba23.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Semnan University Press</PublisherName>
				<JournalTitle>Journal of Modeling and Simulation in Electrical and Electronics Engineering</JournalTitle>
				<Issn>2821-0786</Issn>
				<Volume>6</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>12</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Machine Learning Techniques in Brain Tumor Diagnosis using MRI</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>35</FirstPage>
			<LastPage>50</LastPage>
			<ELocationID EIdType="pii">10953</ELocationID>
			
<ELocationID EIdType="doi">10.22075/mseee.2026.40327.1247</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Pedram</FirstName>
					<LastName>Khoshbakhtloo</LastName>
<Affiliation>Department of Medical Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Abdalhossein</FirstName>
					<LastName>Rezai</LastName>
<Affiliation>Department of Biomedical Engineering, Faculty of Engineering, University of Science and Culture, Tehran, Iran.</Affiliation>
<Identifier Source="ORCID">0000-0001-8529-499X</Identifier>

</Author>
<Author>
					<FirstName>Nasrin</FirstName>
					<LastName>Amiri</LastName>
<Affiliation>Department of Electrical Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>01</Month>
					<Day>14</Day>
				</PubDate>
			</History>
		    <Abstract>Brain tumors require early and precise diagnosis to prevent severe clinical consequences. The complexity of tumor characteristics necessitates expert analysis through MRI, a process that is traditionally labor-intensive. To address this, automated systems leveraging Machine Learning (ML) architectures have emerged. This study evaluates the potential of high-precision computational frameworks for the automated detection and classification of brain tumors in MRI scans. A review of 18 recent studies highlights the effectiveness of ML methods, particularly Convolutional Neural Networks (CNNs), achieving up to 99.85% accuracy. Our research confirms that various ML methods can reliably identify pathological tissues, allowing for the assessment of tumor histology (type) and malignancy grade. Furthermore, the use of multimodal data, such as incorporating PET scans alongside MRI, is recommended to enhance diagnostic outcomes. While CNN-based models show promising results, they require extensive training data; therefore, transfer learning and hybrid models are encouraged to mitigate data scarcity and improve detection accuracy.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Brain tumors</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Brain abnormalities</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Image processing</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">machine learning</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">MRI</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mseee.semnan.ac.ir/article_10953_4f97b077257bc3754bf87d1aa6965739.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Semnan University Press</PublisherName>
				<JournalTitle>Journal of Modeling and Simulation in Electrical and Electronics Engineering</JournalTitle>
				<Issn>2821-0786</Issn>
				<Volume>6</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>12</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Economic Assessment and Optimal Sizing of Energy and Storage Systems of a Grid-Connected Turbo-Expander Based Microgrid with Simultaneous Recovery of Cooling and Electrical Energy at Natural Gas Pressure Reduction Stations</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>51</FirstPage>
			<LastPage>68</LastPage>
			<ELocationID EIdType="pii">10952</ELocationID>
			
<ELocationID EIdType="doi">10.22075/mseee.2026.40212.1244</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Reza</FirstName>
					<LastName>Ghanaee</LastName>
<Affiliation>Semnan Regional Electric Company, Semnan, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Asghar</FirstName>
					<LastName>Akbari Foroud</LastName>
<Affiliation>Electrical and Computer Engineering Faculty, Semnan University, Semnan, Iran.</Affiliation>
<Identifier Source="ORCID">0000-0001-6902-8990</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>12</Month>
					<Day>30</Day>
				</PubDate>
			</History>
		    <Abstract>This paper proposes a novel microgrid configuration integrated with a turbo-expander (TE), in which the recovered cooling and electrical energy are utilized to supply part or all of the microgrid demand. The proposed grid-connected microgrid is designed to optimally select the type and capacity of energy generation and storage systems over a 20-year planning horizon. A multi-objective optimization framework based on the Particle Swarm Optimization (PSO) algorithm is employed to minimize the annualized capital investment as well as operation and maintenance (O&amp;M) costs. The microgrid comprises an internal combustion engine (ICE), photovoltaic (PV) system, battery bank (BB), auxiliary boiler (AB), heat storage tank (HST), absorption chiller (AC), and electric chiller (EC) to meet the electrical, heating, and cooling demands. A comparative economic analysis is performed for two optimal configurations, with and without the TE. The results demonstrate that the TE-based microgrid reduces O&amp;M and emission costs by approximately 34% and 35.2%, respectively, compared with the conventional microgrid. Moreover, cash flow analysis verifies the economic feasibility of the proposed TE-based microgrid.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Turbo-Expander</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Exergy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Microgrid</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Optimal sizing problem</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Cash flow analysis</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mseee.semnan.ac.ir/article_10952_ed7336aa18ce41622a5b41a6a62f4fea.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Semnan University Press</PublisherName>
				<JournalTitle>Journal of Modeling and Simulation in Electrical and Electronics Engineering</JournalTitle>
				<Issn>2821-0786</Issn>
				<Volume>6</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>12</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Co-Optimization of Conservation Voltage Reduction and Uncertainty-Aware Demand Response: A Hybrid IGDT-Fuzzy Programming Approach</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>69</FirstPage>
			<LastPage>85</LastPage>
			<ELocationID EIdType="pii">10962</ELocationID>
			
<ELocationID EIdType="doi">10.22075/mseee.2026.40785.1259</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Hamid</FirstName>
					<LastName>Helmi</LastName>
<Affiliation>Department of Electrical Engineering, Shab.C., Islamic Azad University, Shabestar, Iran.</Affiliation>
<Identifier Source="ORCID">0009-0000-9326-5777</Identifier>

</Author>
<Author>
					<FirstName>Leila</FirstName>
					<LastName>Mohammadian</LastName>
<Affiliation>Department of Electrical Engineering, Shab.C., Islamic Azad University, Shabestar, Iran.</Affiliation>
<Identifier Source="ORCID">0000-0001-5202-1397</Identifier>

</Author>
<Author>
					<FirstName>Taher</FirstName>
					<LastName>Abedinzadeh</LastName>
<Affiliation>Department of Electrical Engineering, Shab.C., Islamic Azad University, Shabestar, Iran.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>03</Month>
					<Day>04</Day>
				</PubDate>
			</History>
		    <Abstract>The integration of distributed generation and demand response programs introduces significant complexity to microgrid management. This paper proposes a comprehensive, stochastic framework for the day-ahead scheduling of a microgrid that simultaneously co-optimizes Demand Response Programs (DRPs) and a Conservation Voltage Reduction (CVR) strategy. The model aims to enhance operational performance, improve reliability, and minimize costs. To address the inherent uncertainties of renewable generation, the framework employs both Time-of-Use (TOU) and incentive-based DRPs, creating a vital link between variable generation and flexible demand. This is complemented by CVR implementation, which leverages voltage-dependent load modeling to achieve further peak load reduction. A key feature of the approach is the use of Information Gap Decision Theory (IGDT) to rigorously model generation uncertainty, providing a robust decision-making foundation. The optimization problem is solved using a Genetic Algorithm (GA) on a test system. Simulation results confirm that the coordinated application of uncertainty-aware DRPs and CVR leads to a substantial reduction in operational costs while significantly improving key microgrid reliability indices, demonstrating the efficacy of the proposed integrated framework.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Active Distribution Networks</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Conservation Voltage Reduction(CVR)</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Demand Response Program(DRP)</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Information Gap Decision Theory(IGDT)</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">multi-objective optimization</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://mseee.semnan.ac.ir/article_10962_aa55a0b1a18d86f1a5a961a0e567efaa.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
